laerdal suction unit battery life

Optional Power/Charging AccessoriesExternal Battery Charger (Cat. laerdal lsu suction laerdal lcsu No. Do not store the LCSU 4 next to a heater. An empty Battery must charge up to 5 hours to reach full capacity. gYpVz*. When the desired vacuum level is reached; unblock the patient tube immediately. Verify proper Canister and Tubing connections.

Follow local protocols for backup suction devices. Jim L.- answered On Saturday, 23 November 2019. Laerdal is not responsible for any consequences of re-use.

0000040543 00000 n suction laerdal unit machines respiratory equipment Resellers may request price quotations online only. NoteInspect all parts when unpacking. Children vacuum range area(marked in blue) on the control panel 289 0 obj <> endobj xref Rx items are not available for resale. Continued efforts to suction with a full canister may cause overflow that will prevent suctioning, damage the pump, void the unit warranty, and lead to prolonged downtime. No. Laerdal LSU Suction Unit 12V 2.3Ah Medical Battery. Internal Battery OperationLCSU 4 is equipped with an Internal Battery, NiMH 12 volt 1.6 Ah.The LCSU 4 will run on battery power unless connected to mains. laerdal suction parts unit through the Vacuum Connector. Rechargeable Battery, NiMH, 12 VDC 2 Ah 886111) or DC Power cord (Cat. Includes: Suction Unit, AC And DCCords,Disposable Canister and Patient Tubing, Battery, Vacuum Tubing and Directions forUse. ====== 2020,Laerdal Medical AS. Instant 30 day credit - NHS/Gov and Care Home Groups use BACS option. 0000009255 00000 n After suctioning, let LCSU 4 run for a moment to allow all suctioned material to flow from the Patient Tube into the Canister. Re-use will lead to an increased risk of cross-contamination, degradation of performance, and/or device malfunction. Damage claims must be made within 5 days of receipt of merchandise. We look forward to the privilege of serving you. suction laerdal cpr Ensure that all connections are secure to prevent leakage. Refrigerated items are only shipped Monday Wednesday and will arrive in 1 2 days. To improve the upright stability, a Wire Stand (Cat. Does not contain latex No. Poor vacuum connection be-tween LCSU 4 and Canister, Follow the procedure for proper assembly of the Canister and Tubing, Lid (800 ml canister only) not properly sealed, Check that the lid is properly secured to the Canister, Check that the Patient tube is not blocked or twisted, or alternately replace the tube. Get FREE ground shipping on all orders $175+*. Both versions of the Laerdal Compact Suction Unit 4 (LCSU 4) come with a carry case for its size. laerdal lsu 0000013019 00000 n the filter is I EPA. Start the test with a fully charged Battery, Turn the vacuum level regulator to maximum. Refer to the Laerdal Global Warranty for terms and conditions. Use of the AC/DC Adapter charger (Cat. If a damaged shipment is received, please note the extent of the damage to the carrier at the time of delivery. For Cleaning and Maintenance, see Chapter 6. Battery run time: Approximately 45 minutes of continuous operation at zero vacuum level (free flow), fully recharged. LEVEL 1 1 Control Unit (CU) and the battery pack, R3 Compact Music System User Manual - Optimized PDF R3 Compact Music System User Manual - Original PDF, PHILIPS 915005630101 Lily base unit User Manual Included Excluded Safety Instructions www.philips-hue.com Use only with Philips Hue 24V, Regal G500 Series Temperature Control Unit User Manual - Optimized PDF Regal G500 Series Temperature Control Unit User, Your email address will not be published. Some goods, such as special order items and items more than 90 days old, etc. 0000003921 00000 n Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. Destinations outside of the 2 day shipping zone must be shipped 2nd Day Air and the air freight charges will apply. 0000003807 00000 n DisposalWhen discarding the LCSU 4, we recommend it be discarded according to local protocol. If rush delivery is requested the cost of freight will be added to your invoice. EMC disturbances cannot affect this behavior.No particular actions are required to maintain safety and performance with regard to electromagnetic disturbances for the expected service life. Battery Charging NoteUse only Laerdal Battery Cat. Our opening hours are from 9 am till 5 pm Monday to Thursday and 8:30 am till 4:30 pm on Fridays. If the Battery level illuminates RED, the battery should be charged. laerdal lsu Unplugging the external power source whilst running will stop the unit from operating. Manufacturers use sponsored listings to help you discover and purchase their listing right where you'll be sure to see them. The Canister is disposable and cannot be cleaned. Operation with High-Efficiency Filter KitTo increase filtration efficiency the Vacuum Tube may be replaced with a High-Efficiency Filter Kit (Cat. External AC OperationTo run on mains power, use the AC/DC Adapter Charger.Plug the smaller DC output cord power connector into the LCSU 4 12V DC Power Input Connection. Check that a suction catheter is attached to the patients suction tube or suction adapter. Municipalities, fire and police departments, recognized volunteer organizations, Government agencies and related: may purchase on terms of Net 30 days from shipping date without prior arrangement. Box 377, 4002 Stavanger, NorwayTel. 884500)DC Power-cord for connection to vehicle 12V DC is required.Plug the smaller power connector into the LCSU 4 12V DC Power Input Connection. Canister capacity: 1000 ml and 1200 ml. The LCSU 4 should only be used by persons trained in the use of medical suction equipment, and according to local protocol. 0000044000 00000 n JavaScript seems to be disabled in your browser. Click-in-place 300 ml canister, no vacuum tube needed, 800 ml canister option when extra volume is needed, Easy to convert between 300 and 800 ml canister version, Internal integrated filter systems for all canisters, Big vacuum regulator dial, with clicking sound, Children vacuum range area (marked in blue) on the control panel, Arrows pointing the vacuum directions High density carry bags, No-tools-necessary field changeable battery. The vacuum level will display on the Suction Level Setting Scale. Perform the Battery Test. 0000003695 00000 n allied suction lsp laerdal l190 1270 list Unable to locate a particular item that you are looking to purchase? Contact Laerdal Medical or your authorized distributor. Extended warranty of up to 3 years is available for your convenience. All other orders are shipped FOB origin and freight charges will be applied at time of shipment. 0000040277 00000 n Contact Laerdal Medical or your authorized distributor for advice. Vacuum Range: 80 500+ mmHg (11 67 kPa) laerdal Easy to convert between the canister systems. The filter automatically stops suction/flow when the canister is full, or the filter becomes saturated if the unit tips onto its side during use. 0000000016 00000 n By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. H\j0l/L` d (E:>kHQfa68v{?/5viYY~;Svyc4&/sxY{p2w7{}Makc*No|=>6yS-%e|lgMi^|[icT\'#"%o5S\+pMlt`Ye"k,`YYY988:888q | + Portable, powerful and highly reliable suction unit. High-efficiency filter kit The Laerdal Compact Suction Unit 4 300ml version weighs 3.3 lbs, and the 800ml version weighs 4.3 lbs. CautionThe LCSU 4 may not achieve the highest vacuum levels when operated at high altitudes. Battery run time: Approximately 45 minutes (free flow), Optional 12V DC Power-cord for connection to vehicle connection, 2 year limited warranty (excluding the canisters, tubing systems and battery. =============================== To prolong Battery lifetime it is recommended to place the Battery on continuous charge. The Scale illuminates Green to indicate the level of vacuum/suction strength, The Light Blue area indicates reduced suction levels for infants and small children. Life-Assist, Inc. shall not be liable for special or consequential damage or injury to person or property which results from the use of these products. Expedited shipping options and pricing are available at checkout. No. If the LCSU 4 does not receive external power, the Low Battery indicator will remain on and the unit performance will drop rapidly leading to a complete LCSU 4 shutdown. ======= may not be eligible for credit. The Canister is disposable and cannot be cleaned. suction laerdal lsu paramedic ambulance emergency pump battery unit laerdal suction 300ml compact unit Register. laerdal suction NoteIf LCSU 4 does not maintain the desired suction performance level, refer to Troubleshooting instructions (see Chapter 7). If you are a dealer or reseller, are using collect billing, or you live outside of the contiguous United States, you do not qualify for free shipping on orders over $175, and different shipping costs apply. 0000012392 00000 n 0000000996 00000 n Specifications are subject to change without notice. Available in two optional styles dependent upon your requirements.

Includes Overflow of suctioned material into the LCSU 4 pump will result in loss of suction and permanent damage to the unit. 0000008169 00000 n Connect the Battery and charge it fully before using the unit. Contact Laerdal Medical or its authorized distributor for additional information if required. When contacting us please try to provide as much information as possible. Please contact our friendly and reliable team on 01305 760750. Charge the Battery for 5 hours. Federal law (USA) restricts the LCSU 4 to sale by or on the order of a physician or other licensed medical authority. The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Like the professionals who use it, the LCSU4 delivers uncompromising patient care. Proximity fields from RF Wireless communications equipment, 380-3% MIix: 27V/m 430-470 MHz: 28V/m 704-787 Ml-lz: 9V/m 800-960 MHz: 28V/m 1700-1990 MI-I z: 28V/m 2400-2470 MHz: 28V/m 5100-5800 MHz: 9V/m, Conducted disturbances induced by RI fields*, 0% UT; 0,5 cycle At 00, 45, 90, 135, 180, 225, 270 and 315, Electrical transient conduction along supply lines, DC power port, Test pulse severity level: III in Table A2 of ISO 7637-2. A $20 service charge will be assessed on all returned checks. 0000040199 00000 n Vacuum Max. Do not immerse the LCSU 4 or allow it to stand in water or other liquids. Recharge the battery as soon as possible. and equipment for the First Responder, Paramedic, EMT and EMS provider. laerdal suction disposable unit complete system which code trailer <<8B4BE664D04642E190B8394AD447E443>]/Prev 1255922/XRefStm 1276>> startxref 0 %%EOF 323 0 obj <>stream Life-Assist, Inc. gives no express or implied warranties on any items shown in its catalog, price list, or otherwise offered for sale and shall not be responsible for the proper use and servicing of goods purchased nor does the company give any express or implied warranty that goods purchased are merchantable or fit for a particular purpose. The battery is warranted for 90 days. 0001134955 00000 n 5-year limitedwarranty (excluding the canisters, tubing systems, and battery. Battery run time. Apply necessary suction therapy.

The Laerdal LSU Nickel Metal Hydride (NiMH) Battery is for use with the unit. Never connect any type of Patient Tubing directly to the LCSU 4 Vacuum Inlet Port Connection. Start earning points today! NoteAll models are shipped with the battery inside the unit, but not connected. UPS Battery Center is in no way implying that any of its products are original equipment manufacturer replacement batteries. AC And DCCords 0000001457 00000 n Thanks for joining the EMP Rewards program. Dublin, OH 43016. Plug the larger connector into the vehicles 12V DC power receptacle. UPS Battery Center Ltd. 555 Riverwalk Pkwy., Suite 100Tonawanda, NY14150 USA. laerdal suction parts unit Copyright 2022 Penncare Inc. All rights reserved | Developed & Powered by Two Loon Software, Bag, LSU Side Pouch - for Carrying Case or Unit, Battery, Laerdal Suction Unit (LSU) NiMH -, Carrying Case, LSU Full Cover, - Bag Only, Charger, Laerdal AC/DC Adapter Charger w/o Power Cord -, Wall Bracket Only for LSU, - w/DC Power Cord, Wall Bracket Only for LSU, - w/AC Power Cord, Wall Bracket Only for LSU, - w/o Power Cord. laerdal bemis airway It is intended for the intermittent operation to remove secretions, blood or vomit from a patients airway to allow ventilation. 0001172433 00000 n 0000002673 00000 n Internally powered/class I equipment type BF, according to IEC 60601-1, Protection class IP33 and standard power supply, Intermittent Operation: 30 minutes on, 30 minutes off. Payment on account will be credited upon receipt at Life-Assists office in Rancho Cordova, California. 5000 Tuttle Crossing Blvd. Most orders are shipped by UPS ground complete within 24 hours (M-F). Earn 1 Rewards point per dollar spent. Start earning, This item might require a License Authorization Form, depending on your state. Learn more, This item is considered a legend device, which means it has special ordering guidelines in certain states. The filter cannot be cleaned or disinfected. Does the Laerdal Compact Suction Unit 4 (LCSU 4) come with tubing and a Yankauer tip? Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the LCSU 4, including cables specified by the Laerdal Medical. Actual product may vary. However other items can be ordered direct from our wide range of suppliers and manufacturers. The LEDs have two brightness levels. Enter your shipping zip code below to see your estimated ground delivery date: Need it sooner? 886116).Ensure Filter IN points towards the WHITE connector, and OUT towards the BLUE. +4751511700Fax +4751523557Laerdal, the Laerdal logo, Laerdal CompactSuction Unit and LCSU are trademarks ofLaerdal Medical AS or its affiliates. 0001137920 00000 n Turn the unit ON by pressing the/OFF button. Approximately 45 minutes (free flow).

: 500+ mmHg (67 kPA) The LCSU 4 is not suitable for use in the presence of flammable liquids or gases; in danger of explosion or fire. Home Laerdal Laerdal LCSU 4 Compact Suction Unit User Guide. CautionDo not cover the Charger. Yes, the Laerdal Compact Suction Unit 4 (LCSU 4), both versions, come with a rechargeable battery and charger. Canister options: on Laerdal LCSU 4 Compact Suction Unit User Guide, Laerdal 3G Plus SimMan Head Skin User Guide. rated with an efficiency of 99.97% down to a particle size of 0.3 gm. Redeem for product credit. HEPA rated bacterial filter laerdal suction Battery = 90 days), Performance Designed for optimal preparation in emergency situations. Compact, powerful, and reliable, Laerdals newest suction unit combines rugged design with lightweight portability, making it an essential tool for every first responder. suction lsu laerdal unit eiremed ie airway management cart Use hand dishwashing liquid or similar that is compatible with the Material hart (see Chapter 9). No. They are for single-patient use only. No. Our warranty is inclusive of shipping costs and is hassle free, the only warranty of this kind in the marketplace.Physical Dimensions:Nominal Voltage: 12VNominal Capacity: 2.3AhTerminal Type: PCWeight: 2 LbsLength: 7.17" (182 mm)Width: 0.91" (23 mm)Height: 2.40" (61 mm)The replacement battery for theLaerdal LSU Suction Unit consists of (1) High Quality 12V 2.3Ah battery.

Sitemap 15

laerdal suction unit battery life